Place of Origin: China
Brand Name: Enargy
Model Number: MT13-12S5-POC
Output Power:

Quick Detail

Place of Origin: China

Brand Name: Enargy

Model Number: MT13-12S5-POC

Output Power:13W

Operating Temperature Range: -2085

Input Voltage Range:9-36Vdc

Output Voltage:5Vdc

Efficiency:88%

Size(L*W*H):29.5*18.5*10.0mm

 

 

Payment & Shipping Terms

Minimum Order Quantity:1pcs

Price: Negotiation

Delivery Time: Negotiation

Supply Ability: 1000Pcs/week

 

 

Key Features

· Output power: 5W

· Wide input range: 9-18Vdc

· High conversion efficiency: 91%

· Line regulation to ±0.5%

· Load regulation to ±1.0%

· Isolation voltage: 1,500V

· Enable (ON/OFF) control

· Output over-current protection

· Hiccup mode short circuit protection

· Over-temperature protection

· Input under-voltage lock-out

· Output voltage trim -8+10 % Vout

 

 

Product Overview

These DC-DC converter modules use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency Active Clamp switching provides high power density with low noise and high efficiency.

 

  1. Electric Characteristics

1.1 Absolute Maximum Ratings

Parameter Min Typ Max Units Notes
Input Voltage     45 Vdc Continuous, non-operating
    36 Vdc Continuous, operating
    45 Vdc Operating transient protection,<100mS
Isolation voltage         Input to output
Operating Temperature -40   100 In view of PCB Temperature
Storage Temperature -65   125  
Enable to Vin- Voltage -0.5   10 Vdc  

 

1.2 Input Characteristics

Parameter Min Typ Max Units Notes
Input Voltage Range 9 12 36 Vdc  
Under-Voltage Lockout   8.6 8.8 Vdc Recovery point
8 8.2   Vdc Protect point
Maximum Input Current     0.75 A Input Vin min,Output full load
Efficiency   86   % Rated Input;Rated Load
Dissipation,standby   0.7   W No Load

 

1.3 Output Characteristics

Parameter Min Typ Max Units Notes
Output Voltage Set Point 4.95 5 5.05 Vdc Nominal input. Output no Load
Output Voltage Range 4.95 5 5.10 Vdc  
Output Current Range 0   2.6 A  
Line Regulation   ±0.02 ±0.50 %  
Load Regulation   ±0.5 ±1.0 %  
Current Limit 2   5 A Output voltage 95% of nominal
Ripple (RMS)   15   mV Nominal input; full load; 20 MHz bandwidth.
Noise(Peak-to-Peak)   60   mV
Maximum Output Cap     4000 μF  

 

1.4 Dynamic Response Characteristics

Parameter Typ Units Notes
Change In Output Current 100 mV 50% to 75% to 50% Iout max; (di/dt= 0.1A/µs).
  100 mV 50% to 75% to 50% Iout max; (di/dt= 0.25A/µs).
Dynamic recovery time 200 µS  
Output rise time 50 mS Starting from vin to vout rise to 90%
Turn-off overshoot 5 %  

 

1.5 Functional Characteristics

Parameter Min Typ Max
bigPhoto
 Mr. Ivy

Tel: 86-755-4153331
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Enargy Power (Shenzhen) Co.,Ltd., [China (Mainland)]


Business Type:Manufacturer
City: Shenzhen
Province/State: Guangdong
Country/Region: China (Mainland)

You May Like: